The IOC operator's duties are primarily ones of observation and proactive intervention. The job revolves around inputs from Xymon and Squared Up, as well as human feedback from sources such as the CSC, Classrooms, etc.

...

Panel
borderColorblack
borderStylesolid
titleNetwork Device Alerts


Note
  • Locate the night's planned maintenance in the Footprints Change and Release Management workspace calendar to ensure the device is not scheduled to be down.
  • Action should be considered for any Squared Up alarm that shows up in the Normal Operations Network View for 20 minutes or longer in duration.  The appropriate steps should be taken as outlined in Section II, Incident On-Call Process found elsewhere in this document.
  • Action should be taken for network issues reported by I-Light (GigaPOP), the ITaP help desk, campus personnel, students, and/or visitors.


8:00 AM to 5:00 PM, Monday through Friday:           
IssueAction
  • Wireless/PAL issues that are being experienced by multiple clients.
  • Reports of multiple data PIC service issues in an area.
  • Report of single HIGH PRIORITY data PIC or wireless PAL outage.
  • Call from I-Light / GigaPOP
  • Follow the normal on-call procedures
Outside of 8:00 AM to 5:00 PM, Monday through Friday:          
IssueAction
  • Wireless/PAL issues that are being experienced by multiple clients in different buildings.
  • Send an email to itns-pdnhlog-ext@lists.purdue.edu to notify Data Networking. If this issue seems to be high priority or widespread it may be justified to escalate to our normal on-call procedures.
  • Reports of multiple data PIC service issues in an area.
  • Report of single HIGH PRIORITY data PIC or wireless PAL outage.
  • Call from I-Light / GigaPOP
  • Follow the normal on-call procedures.

Anchor
networkincident
networkincident

Network Incident On-Call Process

For all SQUARED UP alarms and trouble calls follow the on-call triage process:

For alarms originating from StruxureWare, DCM (Data Center Management) personnel should be notified in addition to proceeding with the Data Networking (ITIS) notification steps outlined below.

  1. Verify that the building that is showing the alarm has electrical power. Pass this information to the on-call and in the follow up email.

    To determine if a device is down on Squared Up due to power outage please start checking the middle screen that networking maintains.

    • If it is on this list do not call.
    • If a building near the building listed on the power outage list is on Squared Up do not call. (Please only call if it is still showing on Squared Up once the power outage time listed is over.)
    (You can look on Purdue Campus Map https://www.purdue.edu/campus_map/ to tell if where buildings are located)

  2. For alarms originating from StruxureWare, DCM personnel should be notified in addition to proceeding with the Data Networking notification steps outlined below.

  3. Call Data Networking (ITIS) Primary On-Call phone (765-494-1591). If no answer, voice mail should be left on the phone and you should wait 5 minutes before proceeding.

  4. A Footprints ticket needs to be made and assigned to ITIS Networking. Put the ticket number in the follow up email. Contact info is the on-calls name.


  5. An email should be sent to itns-pdnhlog-ext@lists.purdue.edu. Justin McIntyre would like to be cc'd in the email also: mcintyrj@purdue.edu
    You do not need to send another email when you try to reach someone. If you leave a message, include this sentence in the body of the email: "We will escalate the on-call process if there is no response within 5 minutes."

  6. Call Data Networking (ITIS) Secondary On-Call phone (765-494-1530). If no answer, voice mail should be left on the phone and you should wait 5 minutes before proceeding.

  7. Call Justin McIntyre at 630-675-7640. If no answer, call Richard Letts 206-790-5837. Wait 5 minutes before proceeding to Step 8.


  8. In the event that none of the individuals from Steps 3 through 6 above has responded, repeat those steps until contact is made. 

Special Notes:

  • Data Networking personnel who are contacted by IOC staff are responsible for providing issue status updates to IOC in a timely fashion.  As a general rule this means that such feedback should be provided once you start investigating an issue, whenever an ETA for resolution has been determined and again when the issue has been resolved.  Additional updates are always welcome as well, especially for extended outages.
  • If Squared Up, itself, ever goes down for more than 20 mins make sure to let Data Networks know that we cannot monitor their devices while it is down. Also send a ticket to the ITAP_Netwroking_II queue regarding it is down. Any part of it (Xymon, Network devices or whole page). Networking supports Squared Up now. Follow normal procedure after you call. i.e follow up email and log. 
  • Battery Alarms in Squared Up: Email Data Networks only. Do NOT call. Make FP ticket, assign to Networking and contact can be left blank or jpublic. Ex's: anything with "APC" in it.


    Ignore the following list of buildings only outside of normal business hours:

    Cases where it is outside of business hours (as is also defined below), please do not call the data networks on-call staff for Squared Up alarms in any of the locations listed in the table down below.  Essentially if the hostname value of the alarm contains a value from the “Squared Up Value” column of the list down below, it should be ignored.  These values are typically fairly static but should any updates need to occur we’ll forward you an updated list.

      • Business Hours – Monday through Friday – 7:00 AM to 5:00 PM
      • (Official Purdue Holidays and Weekends Adjoining those Holiday Dates are Considered to be Non-Business Hours, Superseding the Monday through Friday Standard)
      • Example: 5/25/19 through 5/27/19 (Memorial Day and the weekend adjoining it) would not be considered business hours


    "-trp

    Building Short Name

    Building Long Name

    SquaredUp Value

    -

    Any APC Devices

    "-apc******-"

    -

    Any TRP Devices

    ******-"

    844S

    844 South River Road

    "844s-"

    AC22

    Field Research Facility (ACRE Farm)

    "ac22-"

    AC35

    Pest Lab and Storage Facility (ACRE Farm)

    "ac35-"

    AC41

    Grain Drying Complex - Grain Auger (ACRE Farm)

    "ac41-"

    AC42

    Scales House (ACRE Farm)

    "ac42-"

    AC43

    USDA Soybean Research Lab (ACRE Farm)

    "ac43-"

    AC44

    USDA Rainulator Building Soil Erosion (ACRE Farm)

    "ac44-"

    AC45

    Var Test Facility (ACRE Farm)

    "ac45-"

    AC46

    Headquarters and Shop (ACRE Farm)

    "ac46-"

    AC51

    Weather Facility (ACRE Farm)

    "ac51-"

    AC54

    Crop Diagnostic Training Center (ACRE Farm)

    "ac54-"

    AF01

    Aquaculture (ASREC Farm)

    "af01-"

    AFC

    Anderson Flagship Center

    "afc-"

    AIDC

    Agricultural Information Distribution Center

    "aidc-"

    ASB

    Airport Service Building

    "asb-"

    B201

    Swine Evaluation Headquarters (ASREC Farm)

    "b201-"

    B401

    Poultry and Hatchery Facility (ASREC Farm)

    "b401-"

    B501

    Sheep Research and Teaching Facility (ASREC Farm)

    "b501-"

    B602

    Feed Mill (ASREC Farm)

    "b602-"

    B701

    Swine Office Metabolism Facility (ASREC Farm)

    "b701-"

    B713

    Environmental Research Facility (ASREC Farm)

    "b713-"

    B801

    Farm Operations Shop and Headquarters (ASREC Farm)

    "b801-"

    B901

    Teaching Center and Classroom (ASREC Farm)

    "b901-"

    BBCH

    Purdue Baseball Clubhouse

    "bbch-"

    BBPB

    Purdue Baseball Press Box

    "bbpb-"BECK

    Beck Agricultural Center (ACRE Farm)

    "beck-"

    BTV

    Boiler Television Building

    "btv-"

    CB10

    Beef Building (ASREC Farm)

    "cb10-"

    COAL

    Coal Handling Control/Fire Pump Building

    "coal-"

    FSHR

    TAP Fishers Remote Site

    "fshr"

    GCMB

    Golf Course Maintenance Barn

    "gcmb-"

    GMF

    Grounds Maintenance Facility

    "gmf-"

    GMGF

    Grounds Maintenance Greenhouse Facility

    "gmgf-"

    ICSC

    Indiana Corn and Soybean Innovation Center (ACRE Farm)

    "icsc-"

    IDOT

    Indiana Department of Transportation

    "idot-"

    INDY

    Indianapolis External Site

    "indy-"

    INOK

    Investments Warehouse

    "inok-"

    INSS

    Intramural Storage Shed

    "inss-"

    KKM

    TAP Kokomo Site

    "kkm-"

    LMSB

    Laboratory Material Storage Building

    "lmsb-"

    NA

    TAP New Albany Site

    "na-"

    NACC

    Native American Educational and Cultural Center

    "nacc-"

    PAGE

    Thomas A. Page Pavilion

    "page-"

    PWB

    Purdue West Annex - Building B

    "pwb-"

    PWC

    Purdue West - Building C

    "pwc-"

    RALR

    Stadium Area - Visiting Team Locker Room

    "ralr-"

    SBCH

    Purdue Softball Clubhouse

    "sbch-"

    SBPB

    Purdue Softball Press Box

    "sbpb-"

    SCHO

    Schowe House

    "scho-"

    SD02

    Dairy Research Unit (ASREC Farm)

    "sd02-"

    SIA

    Subaru of Indiana Automotive

    "sia-"

    SOCC

    Purdue Women’s Soccer Building

    "socc-"

    SPUR

    Spurgeon Golf Training Center

    "spur-"

    SWNA

    State Wide New Albany

    "swna-"

    SWSB

    State Wide South Bend

    "swsb-"

    TM02

    Throckmorton Pesticide Building

    "tm02-"

    TM08

    Throckmorton Meigs Building

    "tm08-"

    TM11

    Throckmorton Fruit Barn

    "tm11-"

    TM36

    Throckmorton Farm Crop Barn

    "tm36-"

    TPB

    Rankin Track Press Box

    "tpb-"

    TURF

    Intercollegiate Athletic Sports Turf Building

    "turf-"

    UNPD

    University Police Department

    "unpd-"

    USDA

    USDA Building 1 (ASREC Farm)

    "usda-"

    VCPR

    Veterinary Center for Paralysis Research

    "vcpr-"

    VLAB

    Veterinary Laboratory Animal Building

    "vlab-"

    VOIN

    Voinoff (Samuel) Golf Pavilion

    "voin-"

    VTCH

    Vision Technology 1 Building

    "vtch-"

    VPRB

    Veterinary Pathobiology Research Building

    "vprb-"

    WH9

    Well House 9

    "wh9-"

    WRIT

    John S Wright Forestry Center

    "writ-"

    VPRB

    Veterinary Pathobiology Research Building

    "vprb-"

    WH9

    Well House 9

    "wh9-"

    WRIT

    John S Wright Forestry Center

    "writ-"


Information to Provide When Reporting Network Issues

For Squared Up alarms report the following information from Squared Up when reporting issue:

  1. Date/Time that alarm started (Example: October 26, 10:00 AM)
  2. Affected Device Name (Example: mrdh-285n-c2950-01)
  3. Last Ping (Example: 2017-11-01 11:14:43)

For network issues reported by I-Light / GigaPOP or the ITaP help desk, campus personnel, students, or visitors, report the following information:

  1. Date/Time that issue began or was first noticed (Example: October 26, 10:00 AM)
  2. Affected service (Examples: wireless/PAL, data PIC(s), or I-Light / GigaPOP call back)
  3. Location where problem is occurring (Examples: wireless on 2nd floor of Armstrong, all data PICs in the Forestry building, or I-Light / GigaPOP). Whenever possible obtain a specific building and nearest room number.
  4. Name and phone number (or at least email) of person experiencing/reporting problem

More details can be found on the attached document below:

ITIS-Data Network Incident Resolution Process.docx

...