LEFT: schematic of the inductively coupled plasma (ICP) argon ion source, user sample (red) is placed to the right of the accelerator grid. “Neut.” Refers to the neutralizer. RIGHT: schematic of the Hiden Ion Milling Probe using Secondary Ion Mass Spectrometry (SIMS) for etch End Point Detection (EPD). 


iLab Name

C - AJA ICP Argon Ion Mill Etcher

iLab Kiosk

BRK Etch Core

FIC

Sunil Bhave

Owner

Nick Glassmaker

Location

Cleanroom - Q Bay

Max. Wafer

6"/150 mm

Info Links

Internal | Staff



Tool Highlights

  • Direct physical milling of thin and thick films using argon atoms.

  • Ion beam source : inductively-coupled argon plasma, accelerated up to 900 V in a 14cm broad beam with currents up to 620 mA (Kaufman & Robinson, Inc.).

  • Ar+ ions neutralized using a matched electron beam current before reaching the sample.

  • water-cooled rotating sample carrier can be oriented 0-90 degrees from normal beam incidence.

  • Secondary ion mass spectrometer (SIMS) mounted on the system can be used for manual or automatic endpoint detection (EPD) of milled material by discerning elements based on charge/mass ratio of positive ions (Hiden Analytical).

  • Sample load-lock system saves time with processing.


Type

Materials

Restricted Materials

Available Gases

Max RF Power

Wafer Size

ICP Ion Mill

oxides, metals, polymers

Au

Ar

900 W

6"




iLab Kiosk

eLog: Submit

eLog: View/Edit

Report Problem








Status

UP



Estimated Fix Date and Comment

Responding Staff





Sample Requirements and Preparation

The shared carrier and mask wafers are dirty since they collect all the sputtered material from users' samples.

If you care about contamination of your sample due to re-sputtering of material, you need to provide your own carrier and masks.

About etching gold (Au): please discuss with Neil or the BNC staff in charge before etching Au. 

Sample chuck cooling during etch: Note that thick films require high etch rates (and hence high amounts of heating), so this may mean one needs to load the sample directly on the chuck by venting the chamber (instead of using load lock). This will permit users to apply more torque and get better cooling of the chuck. However, it requires special training.

For EPD, note that argon atomic mass is the same as MgO, so the EPD is not able to sense (ionized) MgO in the large Ar ion background.

Standard Operating Procedure

Standard procedure for tool operation, base off established Birck SOPs.


Process Library

See Internal Resources page. 


Questions & Troubleshooting

Question about tool use or process result?
Answer to question.