The IOC operator's duties are primarily ones of observation and proactive intervention. The job revolves around inputs from Xymon and Squared Up, as well as human feedback from sources such as the CSC, Classrooms, etc.
...
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
On your workstation:
On the monitoring computers:
|
...
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
The IOC Shift Log (found here) is how records are kept during the shift and between shifts. While you are monitoring, one of your duties is to maintain the log. This includes being aware of existing log entries and their implications, making new log entries when certain events occur, and updating log entries as their status changes or new information is reported. The following events should be noted in the log when they occur:
Further information on the process for updating and maintaining the shift log can be found here: IOC: Shift Log Entries. |
...
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
Squared Up will notify IOC of two different types of alerts: Xymon alarms (covered in the next subsection) and Network Device Alerts (covered in the next subsection) . Xymon Alerts:Before calling on any alarm review the following:
After a new Squared Up alert pops up for a production machine, If the alert is still present after 20 minutes Operations will need to call the group responsible for the system. |
...
borderColor | black |
---|---|
borderStyle | solid |
title | Xymon |
Xymon is the web based monitoring tool of choice for Administrators and staff supporting ITSO Windows and Unix processes on the Purdue Campus. It performs a valuable duty, giving the trained eye a quick overview of the hardware and processes that may be out of sync for several key University areas.
In general, Operations staff will only need to respond to Critical (Red) alerts that affect production devices (Servers, Virtual Machines, etc.) All production Xymon alerts should also be reflected in Squared Up. Alarms for McAfee (mcshield.exe) should not be reported unless they last for several hours.
While Operations staff are primarily concerned with Critical (Red) alerts, they should also be familiar with the various other colors of Xymon alerts and their meanings:
1. After a new Xymon critical alert pops up for a production machine, begin considering which group to contact, if any. If the alert is still present after 20 minutes IOC will need to call the system owner.
2. Is the alert for a clustered device? Some systems, like Mailhub, are clustered, and thus can have several alerts before one needs to take action. Generally clustered machines will NOT alarm in Squared Up for individual boxes, but they will in Xymon. This clue can help an operator determine the severity of the Xymon alert. There are some clustered systems which react in the opposite manner - They will alert in Squared Up but not Xymon until critical mass is reached. In these cases ensure enough machines are in alert before contacting the appropriate admins.
3. Locate the night's planned maintenance in the Footprints Change and Release Management Workspace Calendar to ensure the device is not scheduled to be down.
4. Xymon - Click the status icon (pictured below) along the row corresponding to the trouble server.
5. Click on the server name to find further instructions on who to contact or if the alarm should be ignored. Follow any special instructions for the machine OR use the Configuration Management Database (CMDB) to locate the appropriate on-call. For further use on how to use CMDB: Configuration Management Database (CMDB) .
6. Call the on-call and inform them of the situation, affected device, and any other issues that may be cropping up due to the alert. Send a follow-up email. For CPU, memory, and disk alerts, paste the Xymon alert text into the email.
Warning |
---|
If there is no answer from the group's on call number, leave a voicemail. Call back again in 20 minutes. If there is no answer from the group by phone or email after this time, contact the group's manager. If you have questions, consult with CSC / IOC supervisor. |
7. Log the contact, and appropriate follow-up activities.
How to find the system owner (Admin to call):
1. If the system name is clickable, there will be special instructions. Follow those instructions
- These instructions are many times instructions about when NOT to call.
2. Find the system in the Footprints Change and Release management CMDB.
- Search for the name of the system
- Click on the related CI(s) link.
- Click the bubble button CI’s to “Named server”
- Click on the Managed by Relationship, and click “Go To”
- The on call group information should be listed here.
3. If there is no information from the previous steps
- Search the communication log for the alarming system.
- Review past correspondence and determine who to call.
- If the server starts with a “W” it is most likely the windows on call
- If the server starts with an “L” it is most likely the unix on call.(Linux)
- Consult with your coworkers.
- Consult your supervisor, or on call supervisor.
Info | ||||
---|---|---|---|---|
| ||||
Treat a production machine with numerous purple status alerts as if it were a red alert. |
...
borderColor | black |
---|---|
borderStyle | solid |
title | Network Device Alerts |
Note |
---|
|
8:00 AM to 5:00 PM, Monday through Friday:
...
- Wireless/PAL issues that are being experienced by multiple clients.
- Reports of multiple data PIC service issues in an area.
- Report of single HIGH PRIORITY data PIC or wireless PAL outage.
- Call from I-Light / GigaPOP
...
- Follow the normal on-call procedures
Outside of 8:00 AM to 5:00 PM, Monday through Friday:
...
- Wireless/PAL issues that are being experienced by multiple clients in different buildings.
...
- Send an email to itns-pdnhlog-ext@lists.purdue.edu to notify Data Networking. If this issue seems to be high priority or widespread it may be justified to escalate to our normal on-call procedures.
...
- Reports of multiple data PIC service issues in an area.
- Report of single HIGH PRIORITY data PIC or wireless PAL outage.
- Call from I-Light / GigaPOP
...
- Follow the normal on-call procedures.
...
Network Incident On-Call Process
For all SQUARED UP alarms and trouble calls follow the on-call triage process:
For alarms originating from StruxureWare, DCM (Data Center Management) personnel should be notified in addition to proceeding with the Data Networking (ITIS) notification steps outlined below.
...
To determine if a device is down on Squared Up due to power outage please start checking the middle screen that networking maintains.
• If it is on this list do not call.
• If a building near the building listed on the power outage list is on Squared Up do not call. (Please only call if it is still showing on Squared Up once the power outage time listed is over.)
(You can look on Purdue Campus Map https://www.purdue.edu/campus_map/ to tell if where buildings are located)
...
For alarms originating from StruxureWare, DCM personnel should be notified in addition to proceeding with the Data Networking notification steps outlined below.
...
Call Justin McIntyre at 630-675-7640. If no answer, call Richard Letts 206-790-5837. Wait 5 minutes before proceeding to Step 8.
...
Special Notes:
...
Cases where it is outside of business hours (as is also defined below), please do not call the data networks on-call staff for Squared Up alarms in any of the locations listed in the table down below. Essentially if the hostname value of the alarm contains a value from the “Squared Up Value” column of the list down below, it should be ignored. These values are typically fairly static but should any updates need to occur we’ll forward you an updated list.
- Business Hours – Monday through Friday – 7:00 AM to 5:00 PM
- (Official Purdue Holidays and Weekends Adjoining those Holiday Dates are Considered to be Non-Business Hours, Superseding the Monday through Friday Standard)
- Example: 5/25/19 through 5/27/19 (Memorial Day and the weekend adjoining it) would not be considered business hours
...
Building Short Name
...
Building Long Name
...
SquaredUp Value
...
Reason for Ignoring
...
-
...
Any APC Devices
...
"-apc******-"
...
Always ignore APCs in Squared Up
...
-
...
Any Device with the word "test"
...
"test"
...
Test devices are used for testing purposes and not on the production network.
...
844S
...
844 South River Road
...
"844s-"
...
No access, users aren't there after hours
...
AC22
...
Field Research Facility (ACRE Farm)
...
"ac22-"
...
No access, users aren't there after hours, feeds off of BECK
...
AC35
...
Pest Lab and Storage Facility (ACRE Farm)
...
"ac35-"
...
No access, users aren't there after hours, feeds off of BECK
...
AC41
...
Grain Drying Complex - Grain Auger (ACRE Farm)
...
"ac41-"
...
No access, users aren't there after hours, feeds off of BECK
...
AC42
...
Scales House (ACRE Farm)
...
"ac42-"
...
No access, users aren't there after hours, feeds off of BECK
...
AC43
...
USDA Soybean Research Lab (ACRE Farm)
...
"ac43-"
...
No access, users aren't there after hours, feeds off of BECK
...
AC44
...
USDA Rainulator Building Soil Erosion (ACRE Farm)
...
"ac44-"
...
No access, users aren't there after hours, feeds off of BECK
...
AC45
...
Var Test Facility (ACRE Farm)
...
"ac45-"
...
No access, users aren't there after hours, feeds off of BECK
...
AC46
...
Headquarters and Shop (ACRE Farm)
...
"ac46-"
...
No access, users aren't there after hours, feeds off of BECK
...
AC51
...
Weather Facility (ACRE Farm)
...
"ac51-"
...
No access, users aren't there after hours, feeds off of BECK
...
AC54
...
Crop Diagnostic Training Center (ACRE Farm)
...
"ac54-"
...
No access, users aren't there after hours, feeds off of BECK
...
AF01
...
Aquaculture (ASREC Farm)
...
"af01-"
...
No access, users aren't there after hours, feeds off of BECK
...
AFC
...
Anderson Flagship Center
...
"afc-"
...
Far remote site, no access
...
AIDC
...
Agricultural Information Distribution Center
...
"aidc-"
...
No access, users aren't there after hours
...
ASB
...
Airport Service Building
...
"asb-"
...
No access, airport hanger
...
B201
...
Swine Evaluation Headquarters (ASREC Farm)
...
"b201-"
...
No access, users aren't there after hours, feeds off of BECK
...
B401
...
Poultry and Hatchery Facility (ASREC Farm)
...
"b401-"
...
No access, users aren't there after hours, feeds off of BECK
...
B501
...
Sheep Research and Teaching Facility (ASREC Farm)
...
"b501-"
...
No access, users aren't there after hours, feeds off of BECK
...
B701
...
Swine Office Metabolism Facility (ASREC Farm)
...
"b701-"
...
No access, users aren't there after hours, feeds off of BECK
...
B713
...
Environmental Research Facility (ASREC Farm)
...
"b713-"
...
No access, users aren't there after hours, feeds off of BECK
...
B801
...
Farm Operations Shop and Headquarters (ASREC Farm)
...
"b801-"
...
No access, users aren't there after hours, feeds off of BECK
...
B901
...
Teaching Center and Classroom (ASREC Farm)
...
"b901-"
...
No access, users aren't there after hours, feeds off of BECK
...
BBCH
...
Purdue Baseball Clubhouse
...
"bbch-"
...
Seasonal
...
BBPB
...
Purdue Baseball Press Box
...
"bbpb-"
...
Seasonal
...
BTV
...
Boiler Television Building
...
"btv-"
...
No access
...
CB10
...
Beef Building (ASREC Farm)
...
"cb10-"
...
No access, users aren't there after hours, feeds off of BECK
...
COAL
...
Coal Handling Control/Fire Pump Building
...
"coal-"
...
No access
...
FSHR
...
TAP Fishers Remote Site
...
"fshr"
...
Charles Garwood, no access, remote site
...
GCMB
...
Golf Course Maintenance Barn
...
"gcmb-"
...
No access
...
GMF
...
Grounds Maintenance Facility
...
"gmf-"
...
No access
...
GMGF
...
Grounds Maintenance Greenhouse Facility
...
"gmgf-"
...
No access
...
ICSC
...
Indiana Corn and Soybean Innovation Center (ACRE Farm)
...
"icsc-"
...
No access, users aren't there after hours, feeds off of BECK
...
IDOT
...
Indiana Department of Transportation
...
"idot-"
...
Andy Sydelko says they can be ignored
...
INDY
...
Indianapolis External Site
...
"indy-"
...
Gro site - Susan Brock says ignore | Esk site - Mark Sharp says ignore
...
INOK
...
Investments Warehouse
...
"inok-"
...
Andy Sydelko says they can be ignored
...
INSS
...
Intramural Storage Shed
...
"inss-"
...
No access, only one user
...
KKM
...
TAP Kokomo Site
...
"kkm-"
...
Charles Garwood, no access, remote site
...
LMSB
...
Laboratory Material Storage Building
...
"lmsb-"
...
No access
...
NA
...
TAP New Albany Site
...
"na-"
...
Charles Garwood, no access, remote site
...
NACC
...
Native American Educational and Cultural Center
...
"nacc-"
...
No access
...
PAGE
...
Thomas A. Page Pavilion
...
"page-"
...
No access
...
PWB
...
Purdue West Annex - Building B
...
"pwb-"
...
Dennis Lord - Ignore outside of 7:30AM to 4:30 PM
...
PWC
...
Purdue West - Building C
...
"pwc-"
...
Dennis Lord - Ignore outside of 7:30AM to 4:30 PM
...
RALR
...
Stadium Area - Visiting Team Locker Room
...
"ralr-"
...
No access, Seasonal
...
SBCH
...
Purdue Softball Clubhouse
...
"sbch-"
...
Seasonal
...
SBPB
...
Purdue Softball Press Box
...
"sbpb-"
...
Seasonal
...
SCHO
...
Schowe House
...
"scho-"
...
No access
...
SD02
...
Dairy Research Unit (ASREC Farm)
...
"sd02-"
...
No access, users aren't there after hours, feeds off of BECK
...
SIA
...
Subaru of Indiana Automotive
...
"sia-"
...
No access
...
SOCC
...
Purdue Women’s Soccer Building
...
"socc-"
...
No access
...
SPUR
...
Spurgeon Golf Training Center
...
"spur-"
...
No access
...
SWNA
...
State Wide New Albany
...
"swna-"
...
Off campus
...
SWSB
...
State Wide South Bend
...
"swsb-"
...
Off campus
...
TM02
...
Throckmorton Pesticide Building
...
"tm02-"
...
No access, users aren't there after hours
...
TM08
...
Throckmorton Meigs Building
...
"tm08-"
...
No access, users aren't there after hours
...
TM11
...
Throckmorton Fruit Barn
...
"tm11-"
...
No access, users aren't there after hours
...
TM36
...
Throckmorton Farm Crop Barn
...
"tm36-"
...
No access, users aren't there after hours
...
TPB
...
Rankin Track Press Box
...
"tpb-"
...
Seasonal
...
TURF
...
Intercollegiate Athletic Sports Turf Building
...
"turf-"
...
No access, users aren't there after hours
...
UNPD
...
University Police Department
...
"unpd-"
...
This is a backup connection, Mick Kiefer says ignore outside business hours
...
USDA
...
USDA Building 1 (ASREC Farm)
...
"usda-"
...
No access, users aren't there after hours, feeds off of BECK
...
VCPR
...
Veterinary Center for Paralysis Research
...
"vcpr-"
...
Dennis Barnett says ignore until business hours
...
VLAB
...
Veterinary Laboratory Animal Building
...
"vlab-"
...
Dennis Barnett says ignore until business hours
...
VOIN
...
Voinoff (Samuel) Golf Pavilion
...
"voin-"
...
Seasonal, no access
...
VTCH
...
Vision Technology 1 Building
...
"vtch-"
...
No access, not a Purdue building
...
VPRB
...
Veterinary Pathobiology Research Building
...
"vprb-"
...
Dennis Barnett says ignore until business hours
...
WH9
...
Well House 9
...
"wh9-"
...
One user, no access
...
WRIT
...
John S Wright Forestry Center
...
"writ-"
...
No access, users aren't there after hours
...
WH9
...
Well House 9
...
"wh9-"
...
WRIT
...
John S Wright Forestry Center
...
"writ-"
Information to Provide When Reporting Network Issues
For Squared Up alarms report the following information from Squared Up when reporting issue:
- Date/Time that alarm started (Example: October 26, 10:00 AM)
- Affected Device Name (Example: mrdh-285n-c2950-01)
- Last Ping (Example: 2017-11-01 11:14:43)
For network issues reported by I-Light / GigaPOP or the ITaP help desk, campus personnel, students, or visitors, report the following information:
- Date/Time that issue began or was first noticed (Example: October 26, 10:00 AM)
- Affected service (Examples: wireless/PAL, data PIC(s), or I-Light / GigaPOP call back)
- Location where problem is occurring (Examples: wireless on 2nd floor of Armstrong, all data PICs in the Forestry building, or I-Light / GigaPOP). Whenever possible obtain a specific building and nearest room number.
- Name and phone number (or at least email) of person experiencing/reporting problem
More details can be found on the attached document below:
ITIS-Data Network Incident Resolution Process.docx
...
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
|
...
borderColor | black |
---|---|
borderStyle | solid |
title | StruxureWare |
...
- Data Network alarms for the buildings LAMB, LYNN, ERHT, and TEL need to be reported to Data Networks. (I believe this changed to just DCM now - I will follow up)
- “Device status may be inaccurate because an attempt to transfer a device definition file (DDF) failed" alarm. Right click on the device and select "Request device scan" (per the email received by IOC on 05/06/2018).
- Call Todd Turner (68214) if the step above doesn't clear the alarm. If Todd does not answer or respond through email after 20 mins, call Patrick at 765-427-3020(C), 6-1752(W), 765-421-6069(H), if he does not answer cal Jon Miller at 765-414-7646.
- Call Todd Turner (68214) if the step above doesn't clear the alarm. If Todd does not answer or respond through email after 20 mins, call Patrick at 765-427-3020(C), 6-1752(W), 765-421-6069(H), if he does not answer cal Jon Miller at 765-414-7646.
...
- If ALL devices in a room are down, call right away
- Ping the IP Address. If it pings it should clear. If it does not ping or clear after 10 minutes then move to step 3.
- Contact Data Center Management via phone & email.
...
- Include the building, room, device name, and Physical Facilities technician name in the e-mail.
- This is only for the equipment listed below. In all other cases dealing with Physical Facilities requests for permission to do work call Todd Turner at 496-8214.
Generator Test TEL Nodes
- ERHT
- LAMB
- LYNN
- TEL
Crac units Data Centers
- FREH G2 CRAC #1,2,3,4
- FREH G57 CRAC 1
- FREH G60 CRAC 1, ACG-2
- HAAS CRAC 1,2,3
- MATH B60 CRAC 1,2,3
- MATH G72 Chiller
- MATH G109 CRAC 5,6,13
- MATH G190 CRAC 1,12,32
TEL Nodes
- ERHT 5 CRAC 1,2
- LAMB 20 ACG-20,21
- LYNN G168 ACG-40, 41
- TEL 210 CRAC 1,2,3
...
Cameras
StruxureWare also includes monitoring functionality for the cameras in the data centers. This view in StruxureWare should be open at all times on the large screen.
- Please monitor the cameras from time to time to make sure nothing suspicious is going on. Check the Shift Log, Change and Release Management Workspace Calendar and your email for scheduled work. If it appears that the occupants do not belong in the room or are removing things during the night, notify PUPD (48221) to investigate. You will also need to call Todd Turner if you do call PUPD, or if you feel unsure.
- HAAS is considered a lights-out facility with several groups who have card access. The building fire panel is located in the datacenter. The Fire & Safety group works Midnight to 8am doing panel tests across campus, and you will see them or the PUFD in the room from time-to-time.
...
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
NOTE: There is no audio alarm for Siemens. If the Alarms button turns red, call Patrick Finnegan.
Attempt to call their cell first. If you cannot reach Patrick by any of those numbers, call Todd Turner at 68214.
If the IOC receives an automated call regarding the MATH back-up chiller:
|
...
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
General Job Failure Production Control must be contacted within 30 minutes.
Down Agent
File Transfer Failure
Notifications
Further information regarding UC4’s configuration and operation can be found here. |
...
Panel | ||||||
---|---|---|---|---|---|---|
| ||||||
Exchange Outage Exchange outages are very similar to other outages with one exception. When Exchange goes down, Operations staff members are required to inform Purdue Police, Purdue Fire, and the CSC. Contact these groups both at the start, and end of the outage. It may be proper to provide updates, as the situation warrants.
Mcafee ePO Updates There may be times when various campus system admins need exceptions or policies changed in McAfee ePolicy Orchestrator. With the most recent ePO system we are limiting their permission sets, so in an emergency they need to be able to contact someone from the Security Engineering team to implement the changes for them. Follow on-call procedures when an admin calls the IOC with a request like this. ICS (TLT) Tool Page Failure - Tool pages stop working on https://lslab.ics.purdue.edu/icsWeb/a/tools/ . |