Nitric Oxide Anneal

Warning

DO NOT LEAVE TUBE UNATTENDED WHEN Nitric Oxide GAS IS BEING DISPENSED. 

For long anneals either plan for an interval break or have someone else trained on the tube take over. If no-one is present at the tube, it should NOT be dispensing NO gas!


Note
titleLimited Use

Due to cleanliness and contamination concerns, this furnace tube is limited to authorized users. Please contact Rich Hosler for more info.

iLab Name: Nitric Oxide Anneal

iLab Kiosk: BRK Furnace Core
FIC: Shared
Owner: Rich Hosler
Location:
Cleanroom - Q Bay
Maximum Wafer Size: 
3"/75 mm

This tube is currently configured for Prof.

Chen

Morisette's group as of

7

8/

22

15/2024. 


Table of Content Zone
locationtop
styledisc

Table of Contents
outlinetrue
indent25px
stylenone


Overview


General Description

Small bore, high temperature furnace for annealing silicon carbide.

Specifications

  • Max Temperature (°C): 1150°C

  • Max Processing Time (min): n/a

  • Available Gas: Nitric Oxide, and Argon

  • Vacuum Capability: None

  • Max Wafer Size: 3"/75 mm


Sample Requirements and Preparation

If possible, samples should be Piranha cleaned for 10 minutes. If this is not possible due to material incompatibility, a TAI Solvent clean followed by a mandatory DI water rinse step is permissible.


Standard Operating Procedure

Nitric Oxide Anneal Standard Operating Procedure

 

View file
nameNO Anneal SOP 10_26_22.pdf
height400